H3 Continuum Reference Images:
The H3ContinuumReferenceImages node collects up to six optional reference images for use with the Continuum Sampler. These images can provide visual guidance related to appearance or identity, helping the generation process preserve recognizable characteristics from supplied reference material. Empty image slots are ignored, and the remaining images are kept in their prompt order. This node only organizes the references into a bundle; the actual image encoding and use during generation remain handled by the Sampler. If no reference image is supplied, the node produces no reference bundle, allowing the workflow to continue without reference-image guidance.
H3 Continuum Reference Images Input Parameters:
reference_image_4
This optional IMAGE input accepts the fourth reference image in the Continuum reference-image sequence. You can use it to provide additional appearance or identity guidance, such as a person’s facial features, clothing style, character design, or another visual characteristic you want the sampler to consider. If an image is connected, it is included in the packed reference bundle in this position; if it is left empty, the slot is skipped and does not stop the node from processing. The source does not define a numeric minimum, maximum, selectable range, or default image value; the default is empty (None). The input is optional and accepts an image supplied by a compatible image-producing node.
reference_image_5
This optional IMAGE input accepts the fifth reference image in the Continuum reference-image sequence. It can add another appearance or identity reference when several images are needed to communicate a subject clearly or show different relevant visual details. A connected image is retained in sequence order, while an empty slot is skipped. The source does not define a numeric minimum, maximum, selectable range, or default image value; the default is empty (None). The input accepts an image from a compatible image node and does not need to be connected for the node to work.
reference_image_6
This optional IMAGE input accepts the sixth reference image in the Continuum reference-image sequence. Supplying an image here allows the sampler to receive additional visual reference information alongside any earlier connected images. Empty slots are ignored, so leaving this input unconnected has no direct effect other than reducing the number of references available to the sampler. The source does not define a numeric minimum, maximum, selectable range, or default image value; the default is empty (None). The input is optional and must receive an image value from a compatible node when used.
reference_image_7
This optional IMAGE input accepts the seventh reference image in the Continuum reference-image sequence. Use it when another appearance or identity image is useful for describing the subject or maintaining consistency across generated results. If connected, the image is included at its corresponding position; if empty, it is skipped without creating a placeholder reference. The source does not define a numeric minimum, maximum, selectable range, or default image value; the default is empty (None). The input accepts a compatible IMAGE value and can be left disconnected.
reference_image_8
This optional IMAGE input accepts the eighth reference image in the Continuum reference-image sequence. It provides one more optional source of visual guidance for the Continuum Sampler, which can be useful when the subject has several important visual attributes that are better shown through multiple images. The image is included only when connected, and an empty input is skipped while the other supplied images remain available. The source does not define a numeric minimum, maximum, selectable range, or default image value; the default is empty (None). The input must be connected to a compatible image-producing node if you want to use it.
reference_image_9
This optional IMAGE input accepts the ninth reference image in the Continuum reference-image sequence and is the last reference slot provided by this node. It can contribute additional appearance or identity information to the sampler when multiple reference images are needed. If no image is connected, the slot is skipped and the node can still process any other supplied references. The source does not define a numeric minimum, maximum, selectable range, or default image value; the default is empty (None). The input accepts a compatible IMAGE value and is optional.
H3 Continuum Reference Images Output Parameters:
image_references
This output provides an H3_CONTINUUM_IMAGE_REFERENCES value containing the supplied reference images in the order represented by the six reference slots. When at least one image is connected, the output contains a reference-image bundle that the Continuum Sampler can use for its own encoding and generation process. Empty slots remain empty within the collected sequence, while the node’s documented behavior indicates that empty slots are skipped in prompt order when the references are used. When all six inputs are empty, the output value is None, indicating that no reference-image guidance was provided. Connect this output to the compatible reference-image input of the Continuum Sampler.
H3 Continuum Reference Images Usage Tips:
- Connect only the images that provide useful appearance or identity information. The node is designed to work with any number of connected images from zero through six.
- Keep references in a meaningful order. Because the images are collected according to their reference-slot order, place the most important or primary reference in the earliest available slot and add supporting images afterward.
- Use different views or detail images when they communicate information that one image cannot show clearly, such as a front view for identity and an additional image for clothing, color, or overall design.
- Leave unused slots disconnected rather than supplying placeholder images. Empty slots are supported and are skipped when the references are used.
- Connect the
image_referencesoutput directly to the compatible Continuum Sampler input. This node organizes the images but does not perform their encoding; the Sampler remains responsible for interpreting them. - If you want generation without reference-image guidance, leave all six inputs empty. The node will return no reference bundle, which is the expected result for a reference-free workflow.
H3 Continuum Reference Images Common Errors and Solutions:
Image input type mismatch
- Explanation: A connected source does not provide the required
IMAGEdata type. This can happen when a text, mask, latent, model, or other incompatible value is connected to a reference-image input. - Solution: Connect an image-producing node that outputs
IMAGE, such as an image loader or another node that creates an image. Check the connection type shown by the workflow interface.
Missing reference-image bundle input on the Continuum Sampler
- Explanation: The
image_referencesoutput is connected to a Sampler input that does not acceptH3_CONTINUUM_IMAGE_REFERENCES, or the output is not connected at all. The node can collect the images, but another compatible node must consume the bundle. - Solution: Connect
image_referencesto the dedicated reference-image input of the compatible Continuum Sampler. Do not connect it to a regular image, latent, conditioning, or model input.
No reference images supplied
- Explanation: All six optional inputs are empty, so the node returns
Noneinstead of an image-reference bundle. This is expected behavior and does not indicate a failure when you intend to run without reference images. - Solution: For a reference-guided workflow, connect at least one valid image to
reference_image_4,reference_image_5,reference_image_6,reference_image_7,reference_image_8, orreference_image_9. For a reference-free workflow, leave the inputs empty and ensure the downstream Sampler accepts an absent reference bundle.
Invalid or unavailable image connection
- Explanation: The workflow may report an input or execution error when an image connection points to a missing node, an unavailable image, or a node that failed to produce its image output.
- Solution: Check the upstream image node, confirm that its source file or generation step is available, and rerun the workflow. Replace the connection with a valid image-producing node if necessary.
Reference images do not produce the expected result
- Explanation: This node only packages the supplied images. It does not encode them or independently control how strongly the Continuum Sampler follows their visual information. Results may therefore differ depending on the Sampler configuration and the quality or relevance of the references.
- Solution: Use clear, relevant images, organize them in a deliberate order, and adjust the available reference-related settings in the Continuum Sampler. Verify that the bundle is connected to the Sampler’s dedicated reference-image input.
