Zura Wan 2.2 Turbo Switch:
TrendStudioV2Speed switches between a faster, accelerated model path and a quality-focused base model path. It keeps the chosen model and its sampling settings together, so you can change modes without separately adjusting the step count and guidance value elsewhere in your workflow. The source describes these settings as tuned for Wan 2.2 Animate. The node selects between models you provide; it does not create or accelerate a model by itself.
Zura Wan 2.2 Turbo Switch Input Parameters:
base_model
A required MODEL connection for the quality-focused path. When turbo mode is off, the node passes this model through and pairs it with 40 steps and a CFG value of 5.0. Connect the model you want to use for that mode before running. This connection has no numeric minimum, maximum, or default model.
accelerated_model
A required MODEL connection for the turbo path. When turbo mode is on, the node passes this model through and pairs it with the selected accelerated step count and a CFG value of 1.0. Connect an appropriate accelerated model for your workflow; the node does not modify a base model to make it accelerated. This connection has no numeric minimum, maximum, or default model.
turbo
A BOOLEAN switch that chooses the active path. It defaults to True, labeled “Turbo (LightX2V),” which selects accelerated_model. Set it to False, labeled “Quality (40 steps),” to select base_model. The switch also determines which step count and CFG value the node returns. Its options are True and False; numeric minimum and maximum values do not apply.
accelerated_steps
The number of steps returned when turbo is True. The available options are 4, 6, and 8, with 6 as the default, so the minimum available value is 4 and the maximum is 8. The source identifies 6 as the tested default and describes 4 as about a third faster with slightly less edge detail. This setting does not affect the quality path, which always returns 40 steps.
Zura Wan 2.2 Turbo Switch Output Parameters:
model
The MODEL selected by the switch: accelerated_model when turbo is True, or base_model when it is False. Connect this output to the part of your workflow that uses the model. It is the supplied model from the selected path, not a newly generated model.
steps
An INT step count intended to accompany the selected model. In turbo mode, it equals your accelerated_steps choice: 4, 6, or 8. In quality mode, it is always 40. Use this output where your sampling workflow accepts a step count so the setting follows the selected path.
cfg
A FLOAT guidance value intended to accompany the selected model and step count. It is 1.0 in turbo mode and 5.0 in quality mode. Use this output where your sampling workflow accepts CFG; it is a setting supplied by the node, not a measurement of image quality.
Zura Wan 2.2 Turbo Switch Usage Tips:
- Connect both model paths when you expect to switch modes, and connect
model,steps, andcfgto the corresponding downstream settings. This keeps the model and sampling values matched as you toggleturbo. - Start with
turboon andaccelerated_stepsset to the tested default of6. Choose4when faster runs matter more than some edge detail, or try8when you want to compare the available turbo step settings. - Turn
turbooff to use the base model with the node’s fixed quality settings of 40 steps and CFG 5.0. Changingaccelerated_stepswill not change that mode.
Zura Wan 2.2 Turbo Switch Common Errors and Solutions:
Connect the selected model branch before running.
- Explanation: The node raises this error when the model for the active mode is missing:
accelerated_modelwithturboon, orbase_modelwithturbooff. - Solution: Check the
turbosetting, then connect a model to the corresponding input. To use the other connected model, switch to its mode.
A required model input is reported as unconnected
- Explanation: Both model inputs are declared required in the node interface. A workflow may flag a missing connection during validation even though the node selects only one model path when it runs.
- Solution: Connect both
base_modelandaccelerated_model, particularly if you plan to alternate between modes.
accelerated_steps has an invalid selection
- Explanation: The interface offers only
4,6, and8. An unsupported value, such as one introduced through an edited workflow, does not match the declared options. - Solution: Select
4,6, or8in the node interface. Use6to return to the tested default.
