Save 4 hours! We auto-setup your workflow! Free!

Drop your workflow.json — we handle every dependency, custom node, and model. Just open the link and run.

Auto-Setup Workflow Json (Free) Now!
ComfyUI > Nodes > comfyui-lucid-vrp > Anima VRP Adv. Settings (Simple UI)

ComfyUI Node: Anima VRP Adv. Settings (Simple UI)

Class Name

VRPAdvancedSettings

Category
LuCiD VRP
Author
EBEBEEBE (Account age: 68days)
Extension
comfyui-lucid-vrp
Latest Updated
2026-11-05
Github Stars
0.04K

How to Install comfyui-lucid-vrp

Install this extension via the ComfyUI Manager by searching for comfyui-lucid-vrp
  • 1. Click the Manager button in the main menu
  • 2. Select Custom Nodes Manager button
  • 3. Enter comfyui-lucid-vrp in the search bar
After installation, click the Restart button to restart ComfyUI. Then, manually refresh your browser to clear the cache and access the updated list of nodes.

Visit ComfyUI Online for ready-to-use ComfyUI environment

  • Free trial available
  • 16GB VRAM to 80GB VRAM GPU machines
  • 400+ preloaded models/nodes
  • Freedom to upload custom models/nodes
  • 200+ ready-to-run workflows
  • 100% private workspace with up to 200GB storage
  • Dedicated Support

Run ComfyUI Online

Anima VRP Adv. Settings (Simple UI) Description

Configures and validates advanced Anima regional routing settings for LuCiD VRP workflows.

Anima VRP Adv. Settings (Simple UI):

VRPAdvancedSettings provides expert-level control over the configuration used by Anima regional routing in LuCiD VRP. Regional routing helps guide different parts of an image with regional prompt information, and this node packages the advanced routing choices into a consistent, validated configuration. You can use a project-recommended configuration, compare it with the included Sen-sou upstream defaults, or create a custom configuration for controlled experimentation. The node checks that the configuration follows the supported format and that its values meet the defined limits, helping catch invalid settings before they reach the regional-routing system. It does not generate images or apply regional routing itself; its purpose is to prepare reliable settings for the part of your workflow that performs that work.

Anima VRP Adv. Settings (Simple UI) Input Parameters:

preset

Selects which configuration the node actually builds. Options are VRP Recommended, Sen-sou Upstream Defaults, and Custom; the default is VRP Recommended. The two named presets use their stored settings rather than the individual values supplied through the other controls, so manual adjustments only affect the generated configuration when you select Custom. VRP Recommended uses global base routing, base strength 0.20, a start-to-end interval of 0.0–1.0, cross-mask strength 1.0, self-mask strength 0.20, base ratio 0.31, and both injection intervals set to 1. Sen-sou Upstream Defaults uses disabled base routing, base strength 0.20, an interval of 0.0–0.35, cross-mask strength 1.0, self-mask strength 0.20, base ratio 0.10, and both injection intervals set to 1. Custom builds the configuration from the individual controls.

base_mode

Selects the base-routing mode recorded in a custom configuration. Options are disabled, uncovered_only, and global; the default is global. These modes distinguish between disabling base routing, limiting it to areas not covered by regions, and using it globally. This choice determines the scope of the base component in the downstream regional-routing system rather than changing your region definitions. The supplied code validates and stores this selection but does not show the downstream implementation of how base routing is combined with regional information. This control affects the generated configuration only when preset is Custom.

base_strength

Sets the numeric strength of the base component for a custom configuration. The minimum is 0.0, the maximum is 10.0, the default is 0.20, and the adjustment step is 0.01. This gives the downstream regional-routing system a strength value to use alongside the selected base mode. The node itself only validates and records this number; the supplied code does not establish a formula connecting it to visible prompt influence or image appearance. In particular, it should not be interpreted as a simple percentage or as a guarantee that doubling the value doubles an image effect. This control affects the generated configuration only when preset is Custom.

start_percent

Sets the normalized starting position of the regional-routing activation interval in a custom configuration. The minimum is 0.0, the maximum is 1.0, the default is 0.0, and the adjustment step is 0.001. The scale represents a fraction, so 0.0 corresponds to the beginning and 0.35 represents 35% of the interval used by the downstream routing implementation. Together with end_percent, this lets you configure a full or restricted routing window. The start value must not exceed the end value. The supplied code does not show the precise conversion from this interval to sampler execution, so it should not be treated as a guaranteed count of sampling steps. This control affects the generated configuration only when preset is Custom.

end_percent

Sets the normalized ending position of the regional-routing activation interval in a custom configuration. The minimum is 0.0, the maximum is 1.0, the default is 1.0, and the adjustment step is 0.001. A value of 1.0 specifies the end of the interval, while 0.35 specifies an earlier cutoff at 35% on this normalized scale. The recommended preset uses 1.0, whereas the upstream comparison preset uses 0.35. The value must be greater than or equal to start_percent; equal values pass the shown ordering check, but the supplied code does not establish what effect a zero-width interval has downstream. This control affects the generated configuration only when preset is Custom.

cross_mask_strength

Sets the strength value associated with cross-attention masking in a custom configuration. Cross-attention is the mechanism through which image-generation features can refer to text conditioning, so this setting belongs to the text-related side of regional routing. The minimum is 0.0, the maximum is 1.0, the default is 1.0, and the adjustment step is 0.01. Both included presets use 1.0. The node validates and forwards the value, but the supplied code does not show the masking formula or establish that a particular value guarantees complete regional separation or eliminates prompt leakage. Treat it as an advanced routing control rather than a direct image-opacity slider. This control affects the generated configuration only when preset is Custom.

self_mask_strength

Sets the strength value associated with self-attention masking in a custom configuration. Self-attention concerns interactions among the model’s own image-related features, distinguishing this control from the text-related cross-attention setting. The minimum is 0.0, the maximum is 1.0, the default is 0.20, and the adjustment step is 0.01. Both included presets use 0.20. This node stores the value for downstream routing rather than applying a mask itself, and the supplied code does not specify its exact blending behavior or guarantee particular changes to boundaries, detail, or composition. This control affects the generated configuration only when preset is Custom.

base_ratio

Sets the base-ratio value included in a custom regional-routing configuration. The minimum is 0.0, the maximum is 1.0, the default is 0.31, and the adjustment step is 0.01. The project explicitly adopted 0.31 for its recommended configuration after comparisons, while the Sen-sou upstream comparison preset retains 0.10. This makes the parameter an important difference when comparing those configurations. However, the supplied code does not show the formula that uses the ratio, so a value of 0.31 should not be described as a guaranteed 31% contribution from the global prompt or any other specific component. This control affects the generated configuration only when preset is Custom.

cross_inject_every

Sets the injection interval for the cross-attention portion of a custom routing configuration. The minimum is 1, the maximum is 100, the default is 1, and the adjustment step is 1; the value must be an integer. Both included presets use 1. The setting represents how frequently the downstream patch injects its cross-attention routing behavior, but the supplied code does not identify what is being counted, such as attention calls, layers, or sampling steps. Consequently, a value of 2 should not be assumed to mean “every second sampling step,” and larger values should not be assumed to provide a particular speed improvement. This control affects the generated configuration only when preset is Custom.

self_inject_every

Sets the injection interval for the self-attention portion of a custom routing configuration. The minimum is 1, the maximum is 100, the default is 1, and the adjustment step is 1; the value must be an integer. It is separate from cross_inject_every, allowing the two routing paths to carry different interval settings. Both included presets use 1. The node records this interval without performing attention processing, and the supplied code does not define the downstream counting unit or quantify its visual or performance effects. Keep that distinction in mind when testing larger intervals. This control affects the generated configuration only when preset is Custom.

Anima VRP Adv. Settings (Simple UI) Output Parameters:

settings

Returns one structured configuration with the connection type VRP_ADVSETTINGS. This is a settings object, not an image, mask, prompt, or model. It contains the supported format version, currently integer 1, and the validated values for base mode, base strength, activation interval, mask strengths, base ratio, and injection intervals. When you select a named preset, it contains that preset’s stored values; when you select Custom, it contains the values supplied through the individual controls. The configuration is returned as a fresh validated dictionary, giving compatible downstream regional-routing code a consistent set of fields to read. Connect it to an input that explicitly accepts VRP_ADVSETTINGS; the receiving node is responsible for applying the configuration.

Anima VRP Adv. Settings (Simple UI) Usage Tips:

  • Start with VRP Recommended to establish the project’s intended baseline before changing advanced controls.

  • Select Custom before making manual adjustments. With either named preset selected, the node builds the stored preset regardless of the individual control values.

  • To compare the recommended and upstream configurations, keep your prompt, regions, model, seed, and sampling settings unchanged. The presets differ in base_mode, end_percent, and base_ratio, so a preset comparison does not isolate a single cause.

  • To investigate the base-ratio difference specifically, select Custom, keep the other controls at their recommended values, and compare base_ratio 0.31 with 0.10.

  • For an activation-window experiment, keep start_percent at 0.0 and compare end_percent 1.0 with 0.35. This isolates the timing setting without also changing the base mode or ratio.

  • Change one advanced control at a time and record the result. The provided implementation does not establish universal settings for sharper boundaries, better detail, or faster execution.

  • Keep both injection intervals at 1 while establishing a baseline. Test larger values separately, without assuming that their counting unit is sampling steps or that they will improve performance.

  • Use the typed settings connection rather than constructing the configuration manually. This avoids missing fields, extra fields, and unsupported version values.

Anima VRP Adv. Settings (Simple UI) Common Errors and Solutions:

Unknown VRP advanced-settings preset: …

  • Explanation: The preset lookup received a name other than the three supported options. This is most likely with a modified workflow or a programmatic call rather than normal dropdown use.
  • Solution: Select VRP Recommended, Sen-sou Upstream Defaults, or Custom using the node’s dropdown, preserving the exact spelling if you configure the node through an API.

start_percent must not exceed end_percent

  • Explanation: The custom activation interval starts after it ends, such as a start value of 0.8 and an end value of 0.35. - Solution: Set start_percent to a value less than or equal to end_percent. Use 0.0 and 1.0 for the recommended full interval.

base_mode must be one of ('disabled', 'uncovered_only', 'global')

  • Explanation: The configuration contains an unsupported base-mode value.
  • Solution: Choose one of the three listed modes. If you edited workflow data manually, restore the exact lowercase spelling, including the underscore in uncovered_only.

base_strength must be between 0.0 and 10.0

  • Explanation: The custom base-strength value is outside the permitted range.
  • Solution: Enter a value from 0.0 through 10.0. Restore 0.20 if you want the recommended starting point.

start_percent must be between 0.0 and 1.0

  • Explanation: The start position is outside the normalized interval, possibly because a percentage such as 35 was entered instead of 0.35. - Solution: Enter a value from 0.0 through 1.0 and make sure it does not exceed end_percent.

end_percent must be between 0.0 and 1.0

  • Explanation: The end position is outside the normalized interval.
  • Solution: Enter a value from 0.0 through 1.0. Use 0.35 for 35% or 1.0 for the end of the interval, and keep it greater than or equal to start_percent.

cross_mask_strength, self_mask_strength, or base_ratio must be between 0.0 and 1.0

  • Explanation: One of these controls is outside its allowed range. The actual error names the individual field, for example, base_ratio must be between 0.0 and 1.0.
  • Solution: Keep each value between 0.0 and 1.0. The recommended values are 1.0 for cross_mask_strength, 0.20 for self_mask_strength, and 0.31 for base_ratio.

advanced_settings must be a VRP_ADVSETTINGS object

  • Explanation: The settings validator received something other than a dictionary-based settings object, such as text or an unrelated value.
  • Solution: Supply the settings output from VRPAdvancedSettings to a compatible settings input rather than substituting another data type.

VRP_ADVSETTINGS has invalid fields

  • Explanation: The configuration does not contain exactly the expected fields. Missing fields and additional unrecognized fields are both rejected.
  • Solution: Rebuild the configuration with VRPAdvancedSettings. If you construct it programmatically, include the version field and all nine advanced-setting fields, without extra entries such as preset.

Unsupported VRP_ADVSETTINGS version; expected integer 1

  • Explanation: The configuration’s version is missing the required integer representation or uses an unsupported version. A string such as "1" does not meet the explicit integer check.
  • Solution: Regenerate the configuration with this node. For a programmatically constructed configuration, use integer 1 for the version.

Injection interval is outside the node’s allowed integer range

  • Explanation: This describes an input constraint rather than a quoted validator message: cross_inject_every and self_inject_every accept whole numbers from 1 through 100, so values such as 0, 101, or 1.5 do not match the declared interface.
  • Solution: Enter a whole number between 1 and 100 for each interval. Use 1 for both to return to the values shared by the included presets.

Anima VRP Adv. Settings (Simple UI) Related Nodes

Go back to the extension to check out more related nodes.
comfyui-lucid-vrp
RunComfy
Copyright 2025 RunComfy. All Rights Reserved.

RunComfy is the premier ComfyUI platform, offering ComfyUI online environment and services, along with ComfyUI workflows featuring stunning visuals. RunComfy also provides AI Models, enabling artists to harness the latest AI tools to create incredible art.

Anima VRP Adv. Settings (Simple UI)