Save 4 hours! We auto-setup your workflow! Free!

Drop your workflow.json — we handle every dependency, custom node, and model. Just open the link and run.

Auto-Setup Workflow Json (Free) Now!
ComfyUI > Nodes > ComfyUI-MiniMaxH3-Contex-Loop > MiniMax H3 Patch Priority

ComfyUI Node: MiniMax H3 Patch Priority

Class Name

MiniMaxH3PatchPriority

Category
conditioning/minimax/contex_loop
Author
ethanfel (Account age: 3377days)
Extension
ComfyUI-MiniMaxH3-Contex-Loop
Latest Updated
2026-08-13
Github Stars
0.17K

How to Install ComfyUI-MiniMaxH3-Contex-Loop

Install this extension via the ComfyUI Manager by searching for ComfyUI-MiniMaxH3-Contex-Loop
  • 1. Click the Manager button in the main menu
  • 2. Select Custom Nodes Manager button
  • 3. Enter ComfyUI-MiniMaxH3-Contex-Loop in the search bar
After installation, click the Restart button to restart ComfyUI. Then, manually refresh your browser to clear the cache and access the updated list of nodes.

Visit ComfyUI Online for ready-to-use ComfyUI environment

  • Free trial available
  • 16GB VRAM to 80GB VRAM GPU machines
  • 400+ preloaded models/nodes
  • Freedom to upload custom models/nodes
  • 200+ ready-to-run workflows
  • 100% private workspace with up to 200GB storage
  • Dedicated Support

Run ComfyUI Online

MiniMax H3 Patch Priority Description

Manages and prioritizes compatibility patches in H3 framework, ensuring integrity and functionality of behaviors.

MiniMax H3 Patch Priority:

The MiniMaxH3PatchPriority node is designed to manage and prioritize compatibility patches within the H3 framework, specifically focusing on conditioning data flow. Its primary function is to ensure that the most current and compatible H3 patch is utilized, thereby maintaining the integrity and functionality of the H3-Multishot and SolAttn behaviors. This node acts as a gatekeeper, allowing only recognized and compatible patches to be applied, while rejecting unknown or incompatible wrappers. By doing so, it ensures that the conditioning data is passed through unchanged, preserving the intended behavior of the workflow. This node is particularly useful in complex workflows where multiple patches might be present, as it enforces a strict preference for the current pack's patch, ensuring process-global consistency after execution.

MiniMax H3 Patch Priority Input Parameters:

conditioning

The conditioning parameter serves as a pass-through for conditioning data, which is crucial for maintaining the flow of information between nodes in a workflow. This parameter should be directly connected between Ref2VA/I2V and the Contex Loop Context to ensure that the node executes before any continuation guides are added. It does not alter the conditioning data but ensures that the node's logic is applied before any further processing. This parameter does not have specific minimum, maximum, or default values, as it is intended to pass through the exact input conditioning data unchanged.

MiniMax H3 Patch Priority Output Parameters:

conditioning

The conditioning output parameter returns the exact input conditioning data, unchanged. This ensures that the data integrity is maintained throughout the workflow, allowing subsequent nodes to receive the same conditioning information that was input into this node. It is crucial for maintaining the consistency of the workflow's logic and behavior.

status

The status output parameter provides a string that indicates the result of the patch priority claim. This status message informs you whether the current pack's patch has successfully claimed ownership, detailing the active native or legacy patch path and ownership result. This output is essential for debugging and ensuring that the correct patch is being utilized in the workflow.

MiniMax H3 Patch Priority Usage Tips:

  • Ensure that the conditioning input is correctly wired between Ref2VA/I2V and the Contex Loop Context to guarantee that the node executes at the appropriate stage in the workflow.
  • Use this node in workflows where multiple patches might be present to enforce the use of the most current and compatible patch, thereby maintaining consistency and avoiding conflicts.

MiniMax H3 Patch Priority Common Errors and Solutions:

MiniMaxH3.extra_conds is unavailable

  • Explanation: This error occurs when the MiniMaxH3 class does not have the extra_conds attribute available, possibly due to an incorrect setup or missing dependencies.
  • Solution: Ensure that the MiniMaxH3 class is correctly initialized and that all necessary dependencies are installed and properly configured.

layout activation failed its compatibility test

  • Explanation: This error indicates that the layout activation process did not pass the required compatibility checks, which are necessary for the patch to be applied.
  • Solution: Verify that the patch being applied is compatible with the current setup and that all required conditions for activation are met. Check for any conflicting patches that might be causing the failure.

MiniMax H3 Patch Priority Related Nodes

Go back to the extension to check out more related nodes.
ComfyUI-MiniMaxH3-Contex-Loop
RunComfy
Copyright 2025 RunComfy. All Rights Reserved.

RunComfy is the premier ComfyUI platform, offering ComfyUI online environment and services, along with ComfyUI workflows featuring stunning visuals. RunComfy also provides AI Models, enabling artists to harness the latest AI tools to create incredible art.

MiniMax H3 Patch Priority