ComfyUI > Nodes > ComfyUI-WanVaceAdvanced > VaceStrengthTester

ComfyUI Node: VaceStrengthTester

Class Name

VaceStrengthTester

Category
WanVaceAdvanced
Author
drozbay (Account age: 3591days)
Extension
ComfyUI-WanVaceAdvanced
Latest Updated
2025-12-12
Github Stars
0.06K

How to Install ComfyUI-WanVaceAdvanced

Install this extension via the ComfyUI Manager by searching for ComfyUI-WanVaceAdvanced
  • 1. Click the Manager button in the main menu
  • 2. Select Custom Nodes Manager button
  • 3. Enter ComfyUI-WanVaceAdvanced in the search bar
After installation, click the Restart button to restart ComfyUI. Then, manually refresh your browser to clear the cache and access the updated list of nodes.

Visit ComfyUI Online for ready-to-use ComfyUI environment

  • Free trial available
  • 16GB VRAM to 80GB VRAM GPU machines
  • 400+ preloaded models/nodes
  • Freedom to upload custom models/nodes
  • 200+ ready-to-run workflows
  • 100% private workspace with up to 200GB storage
  • Dedicated Support

Run ComfyUI Online

VaceStrengthTester Description

Utility node for testing strength combinations in VACE models, visualizing reference and control strength impacts for model optimization.

VaceStrengthTester:

The VaceStrengthTester is a utility node designed to facilitate the testing of various strength combinations within VACE models. Its primary purpose is to help you visualize how different reference and control strengths influence the output of these models. By allowing you to experiment with different strength settings, this node provides valuable insights into the behavior of VACE models, enabling you to fine-tune the model's performance according to your specific needs. This node is particularly beneficial for AI artists who wish to explore the effects of varying strengths on their creative outputs, offering a straightforward method to assess and adjust the model's conditioning parameters.

VaceStrengthTester Input Parameters:

positive

This parameter represents the conditioning input required by the node. It is a crucial component that influences the model's behavior and output, serving as the baseline or starting point for the strength adjustments.

reference_strength

The reference strength parameter is a floating-point value that determines the intensity of the reference frames in the VACE model. It ranges from 0.0 to 10.0, with a default value of 1.0. Adjusting this parameter affects how strongly the reference frames influence the model's output, allowing you to control the balance between reference and control frames.

control_strength

Similar to the reference strength, the control strength is a floating-point value that dictates the intensity of the control frames. It also ranges from 0.0 to 10.0, with a default value of 1.0. This parameter enables you to fine-tune the influence of control frames on the model's output, providing flexibility in achieving the desired artistic effect.

frame_count

The frame count parameter is an integer that specifies the number of frames to be processed by the node. It can range from 1 to 1000, with a default value of 20. This parameter determines the duration or extent of the strength testing, allowing you to control the scope of the visualization.

custom_strength_list

This optional parameter is a string that allows you to input a custom list of strength values, separated by commas. If provided, it overrides the default reference and control strength settings. The custom list can be multiline and is useful for testing specific strength sequences. If the list is shorter than the frame count, it will be padded; if longer, it will be truncated.

VaceStrengthTester Output Parameters:

conditioning

The conditioning output is a modified version of the input conditioning, adjusted according to the specified strength parameters. This output reflects the changes made by the node and serves as the basis for further processing or visualization in the VACE model.

strength_info

This output is a string that provides information about the strength settings used during the test. It includes details about the reference and control strengths, as well as any custom strength list applied. This information is valuable for understanding the context of the test and interpreting the results.

VaceStrengthTester Usage Tips:

  • Experiment with different combinations of reference and control strengths to see how they affect the model's output. This can help you find the optimal settings for your specific artistic goals.
  • Use the custom strength list to test specific sequences of strengths, which can be particularly useful for creating animations or dynamic effects.
  • Start with the default settings and gradually adjust the strengths to understand their impact before applying more complex configurations.

VaceStrengthTester Common Errors and Solutions:

Invalid custom list, using ref:<reference_strength>, ctrl:<control_strength> for <frame_count> frames

  • Explanation: This error occurs when the custom strength list provided is not valid, possibly due to incorrect formatting or non-numeric values.
  • Solution: Ensure that the custom strength list is a comma-separated string of numeric values. Check for any non-numeric characters or formatting issues and correct them before re-running the node.

If vace_strength is a list, it must have length <vace_latent_length>, got <length>

  • Explanation: This error indicates that the custom strength list does not match the expected length required by the model.
  • Solution: Adjust the length of the custom strength list to match the required length, either by adding more values or truncating the list as necessary.

VaceStrengthTester Related Nodes

Go back to the extension to check out more related nodes.
ComfyUI-WanVaceAdvanced
RunComfy
Copyright 2025 RunComfy. All Rights Reserved.

RunComfy is the premier ComfyUI platform, offering ComfyUI online environment and services, along with ComfyUI workflows featuring stunning visuals. RunComfy also provides AI Models, enabling artists to harness the latest AI tools to create incredible art.