ComfyUI > Nodes > WWAA-CustomNodes > 🪠️ WWAA Nested Loop Counter

ComfyUI Node: 🪠️ WWAA Nested Loop Counter

Class Name

WWAA_NestedLoopCounter

Category
🪠️WWAA
Author
hgabha (Account age: 503days)
Extension
WWAA-CustomNodes
Latest Updated
2025-05-11
Github Stars
0.02K

How to Install WWAA-CustomNodes

Install this extension via the ComfyUI Manager by searching for WWAA-CustomNodes
  • 1. Click the Manager button in the main menu
  • 2. Select Custom Nodes Manager button
  • 3. Enter WWAA-CustomNodes in the search bar
After installation, click the Restart button to restart ComfyUI. Then, manually refresh your browser to clear the cache and access the updated list of nodes.

Visit ComfyUI Online for ready-to-use ComfyUI environment

  • Free trial available
  • 16GB VRAM to 80GB VRAM GPU machines
  • 400+ preloaded models/nodes
  • Freedom to upload custom models/nodes
  • 200+ ready-to-run workflows
  • 100% private workspace with up to 200GB storage
  • Dedicated Support

Run ComfyUI Online

🪠️ WWAA Nested Loop Counter Description

Facilitates management of nested loops in ComfyUI for precise iteration control in complex workflows.

🪠️ WWAA Nested Loop Counter:

The WWAA_NestedLoopCounter node is designed to facilitate the management of nested loops within the ComfyUI environment, providing a structured way to handle iterative processes. This node is particularly useful for scenarios where you need to perform operations in a sequence that involves multiple levels of iteration, such as processing multi-dimensional data or executing complex workflows that require nested loops. By maintaining and updating two counters, i and j, the node allows you to track the current state of each loop, ensuring that operations are executed in the correct order. This functionality is essential for tasks that require precise control over iteration sequences, making it a valuable tool for AI artists who need to automate repetitive tasks or manage complex data processing workflows.

🪠️ WWAA Nested Loop Counter Input Parameters:

max_value

The max_value parameter defines the upper limit for both counters i and j. When either counter reaches this value, it triggers a reset or an increment in the next level of the loop. This parameter is crucial for controlling the loop's termination condition, ensuring that the iteration does not exceed the desired range. The max_value should be set according to the specific requirements of your task, with no explicit minimum or maximum values provided in the context, but it should be a positive integer that reflects the number of iterations needed.

increment

The increment parameter specifies the step size for each iteration of the counters. It determines how much the counter j is increased in each step, and subsequently, how i is incremented when j reaches the max_value. This parameter allows you to control the granularity of the iteration process, enabling you to skip certain values or adjust the pace of the loop. The increment should be a positive integer, and its value should be chosen based on the desired iteration speed and the specific requirements of your task.

reset

The reset parameter is a boolean flag that, when set to true, resets both counters i and j to zero. This is useful for restarting the iteration process from the beginning, either to repeat a task or to ensure that the loop starts fresh for a new set of operations. The reset parameter provides a simple mechanism to control the flow of the loop, allowing you to easily manage the start and stop conditions of your iterative processes.

🪠️ WWAA Nested Loop Counter Output Parameters:

i

The i output represents the current value of the outer loop counter. It is an integer that tracks the number of times the outer loop has been executed. This output is essential for understanding the current state of the iteration process, especially in nested loops where the outer loop controls the broader sequence of operations.

j

The j output is the current value of the inner loop counter. Like i, it is an integer that indicates the current position within the inner loop. This output is crucial for tasks that require detailed tracking of the iteration process, as it provides insight into the finer steps of the loop sequence.

float(i)

The float(i) output is the floating-point representation of the i counter. This output is useful for scenarios where a floating-point value is required for further processing or integration with other nodes that expect non-integer inputs.

float(j)

The float(j) output is the floating-point representation of the j counter. Similar to float(i), this output is beneficial for tasks that require floating-point precision or compatibility with other nodes that operate on non-integer values.

debug_msg

The debug_msg output provides a detailed message about the current execution state, including the current values of i and j, and any changes that have occurred during the iteration. This output is particularly useful for debugging and understanding the flow of the loop, as it offers insights into the internal workings of the node and helps identify any issues or unexpected behavior.

🪠️ WWAA Nested Loop Counter Usage Tips:

  • Use the max_value parameter to control the total number of iterations for your loops, ensuring it aligns with the specific requirements of your task.
  • Adjust the increment parameter to fine-tune the iteration process, allowing you to skip unnecessary steps or control the pace of the loop.
  • Utilize the reset parameter to restart the loop sequence when needed, providing flexibility in managing iterative processes.

🪠️ WWAA Nested Loop Counter Common Errors and Solutions:

Counter Exceeds Maximum Value

  • Explanation: This error occurs when the counters i or j exceed the specified max_value, potentially due to incorrect parameter settings.
  • Solution: Ensure that the max_value is set correctly and that the increment parameter is appropriate for the desired iteration range. Adjust these parameters to prevent the counters from exceeding their limits.

Unexpected Reset Behavior

  • Explanation: The loop may reset unexpectedly if the reset parameter is not managed correctly, leading to unintended restarts of the iteration process.
  • Solution: Verify that the reset parameter is only set to true when a reset is intended. Use conditional logic to control when the reset should occur, ensuring it aligns with your workflow requirements.

🪠️ WWAA Nested Loop Counter Related Nodes

Go back to the extension to check out more related nodes.
WWAA-CustomNodes
RunComfy
Copyright 2025 RunComfy. All Rights Reserved.

RunComfy is the premier ComfyUI platform, offering ComfyUI online environment and services, along with ComfyUI workflows featuring stunning visuals. RunComfy also provides AI Playground, enabling artists to harness the latest AI tools to create incredible art.